ABB |M2JA-W outdoor explosion-proof electric motor

Category:ABB Motor

+86-152-9510-6006 Online consultation

M2JA series flameproof three-phase asynchronous motor is the manufacturing technology of ABB motor company the latest application of flameproof motor, combined with the characteristics of Chinese GB 3836-2000 standard and the development of the project

The most advanced domestic factories with 4 flameproof motor (Ex d||C) products (T1-T4 temperature group).

1. standard

M2JA series flameproof motor in accordance with the following criteria

international standardIEC60079-0 60079-1
Chinese standardGB3836.1 3836.2
European standardEN5001450018
American StandardULTwo thousand two hundred and seventy-nine
Russian standardR O C TP51330.0 P51330.1
Japan standardJISC09300931

Place 2.Ex D motor

1 explosion proof is divided into: 1 Zone 0, zone 2.

regionRegional definitionsWith the explosion-proof motor
The 0 DistrictExplosive areaThere is no suitable explosion-proof motor
The 1 DistrictExplosive areaFlameproof d"
The 2 DistrictAccidental explosion areaFlameproof type "d" increased safety "e", "nA" motor non-sparking

2 place

Petroleum, natural gas and chemical industry, in the production process may produce all kinds of flammable gases or vapors, such as oil refineries with propane, butane, gasoline, ethylene and acetylene; fertilizer plant ammonia, methanol, carbon monoxide, water gas etc..These substances are mixed with the air after the formation of an explosive mixture, if the mixture is in an explosive temperature, and in case of fire, it will cause serious accident of explosion.

Squirrel cage motor does not produce sparks in normal circumstances, but in the process of operation, due to the winding insulation damage and aging caused by short circuit spark; or because of conductive part connecting relaxation caused by arc, or due to mechanical failure and other causes of motor overload and block to produce high temperature, become a point source.

Therefore, we must focus on the various types of explosion-proof motor, spark arc and dangerous temperature take effective measures.

"Ex D" type flameproof motor is a form of explosion-proof explosion-proof motor, the casing can withstand damage without any joints or through the shell structure gap penetrated inside the casing of a flammable mixture in internal explosion, and will not cause the ignition of an external explosive gas environment, a variety of gas or steam formation the.

3 technical characteristics


High efficiency.

To achieve the level of motor efficiency standard European CEMEP-EU two level, with the limited value of People's Republic of China national standard GB18613-2002 miniature three-phase asynchronous motor energy efficiency.

Dual frequency and wide voltage

The voltage range of 220V-690V, 50HZ and 60HZ power supply.

Low noise.

Through the optimization of electromagnetic design, ventilation condition, structure and technology of M2JA series motor with low noise.

- bearing high load capacity

Standard motor selection of deep groove bearings, long service life, high motor 80-132 Center for permanent lubrication, 160-355 is provided with a refueling device.

- good reliability

The motor is fully enclosed air cooling structure, protection grade IP55, materials and processes to meet environmental requirements. The motor has high mechanical strength, durability, rust and corrosion resistance strong. Winding reliability, a class F insulation structure, B assessment. According to user needs and increase the PTC thermistor or thermal switch.

4 model description

M2JA 112 M 4 A
M2JA-- type marker 112-- frame (with the shaft center high mm)
M-- code of frame length (S- short frame, M- machine, L- machine)
4-- number A-- (A- core length short core and long core B-)

Explosion proof mark 5 for flameproof motor

Ex D C T4 ||
Ex-- marker d-- flameproof explosion-proof electrical equipment factory ||--
C-- flameproof grade T4-- temperature group

6 installation structure

B3 frame with foot, head cover without flange
B5 frame without foot, head cover with flange
B35 frame with foot, head cover with flange

7 working conditions

And the ambient air temperature varies with the seasons but not more than -15 DEG -40 DEG
- altitude does not exceed 1000M
Rated frequency: 50HZ/60HZ
Work voltage: 220-690V
Work mode: continuous (S1)

A. Start mode: full voltage starting, Y- delta starting or reactance starting
A. Transmission mode: use the elastic coupling of spur gears
A. Insulation and heating: F. But the stator winding temperature rise limit 80K, According to the B class (resistance). Bearing The allowable temperature does not exceed 95 C (thermometer).
A. Cooling method: IC411

8 bearing type and cable entrance

 Bearing (NSK bearing) (optional SKF bearing)

Standard bearing type cable interface

D-end N-end mm center high pole number
80M 2,4,6 6204-DDUC3 6204-DDUC3 1-M25*1.5 1-M16*1.5
90S 2,4,6 6205-DDUC3 6205-DDUC3 1-M25*1.5 1-M16*1.5
90L 2,4,6 6205-DDUC3 6205-DDUC3 1-M25*1.5 1-M16*1.5
100L 2,4,6,8 6206-DDUC3 6206-DDUC3 1-M32*1.5 1-M16*1.5
112M 2,4,6,8 6207-DDUC3 6206-DDUC3 1-M32*1.5 1-M16*1.5
132S 2,4,6,8 6208-DDUC3 6208-DDUC3 1-M32*1.5 1-M16*1.5
132M 2,4,6,8 6208-DDUC3 6208-DDUC3 1-M32*1.5 1-M16*1.5
160M 2,4,6,8 6309-ZZC3 6309-ZZC3 1-M40*1.5 1-M16*1.5
160L 2,4,6,8 6309-ZZC3 6309-ZZC3 1-M40*1.5 1-M16*1.5
180M 2,4,6,8 6310-ZZC3 6309-ZZC3 1-M40*1.5 1-M16*1.5
180L 2,4,6,8 6310-ZZC3 6309-ZZC3 1-M40*1.5 1-M16*1.5
200L 2,4,6,8 6312-ZZC3 6310-ZZC3 2-M50*1.5 1-M16*1.5
225S 2,4,6,8 6313-ZZC3 6212-ZZC3 2-M50*1.5 1-M16*1.5
225M 2,4,6,8 6313-ZZC3 6212-ZZC3 2-M50*1.5 1-M16*1.5
250M 2,4,6,8 6315/C3 6313/C3 2-M63*1.5 1-M16*1.5
280S 2 6316/C4 6316/C4 2-M63*1.5 1-M16*1.5
280S 4,6,8 6316/C3 6316/C3 2-M63*1.5 1-M16*1.5

280M 2 6316/C4 6316/C4 2-M63*1.5 1-M16*1.5

280M 4,6,8 6316/C3 6316/C3 2-M63*1.5 1-M16*1.5
315S 2 6316/C4 6316/C4 2-M63*1.5 2-M20*1.5
315S 4,6,8 6319/C3 6316/C3 2-M63*1.5 2-M20*1.5
315M 2 6316/C4 6316/C4 2-M63*1.5 2-M20*1.5
315M 4,6,8 6319/C3 6316/C3 2-M63*1.5 2-M20*1.5
315L 2 6316/C4 6316/C4 2-M63*1.5 2-M20*1.5
315L 4,6,8 6319/C3 6316/C3 2-M63*1.5 2-M20*1.5
355M 2 6319M/C4 6319M/C4 2-M63*1.5 2-M20*1.5
355M 4,6,8 6322/C3 6319/C3 2-M63*1.5 2-M20*1.5
355L 2 6319M/C4 6319M/C4 2-M63*1.5 2-M20*1.5
355L 4,6,8 6322/C3 6319/C3 2-M63*1.5 2-M20*1.5

9 voltage and performance parameters

Wide voltage design adopts M2JA series motor, motor efficiency, in various voltage condition of the power factor and speed change slightly.

50Hz:220-240V/380-420V; 380-420V/660-690V, 60Hz:460V (>3KW / delta delta /Y = 3KWY)

Note: >3KW (380-420V, 440-460V, 660-690V) = 3KW (220-240V, 380-420V, 440-460V)

If the user needs a specific working voltage, can be supplied according to special requirements.


The performance of the motor changes (with 400V to ensure that the value of the ratio of%)

Output

I s / I N

T s /T N

T max/ T N

100100

90100

90100

90100

100100

90106

90106

90106

100100

90100

90100

90100

And without prior notice, ABB reserves the right to modify the design of motor technical specifications